Compliance UL325.
Wizard Works Security Systems understands the importance of providing and installing safe products. We are Certified Automatic Gate Operator Installers (CAGOI) and Certified Automatic Gate System Designers (CAGSD) UL325 dictates the safety requirements for all automatic gates. All automatic gates must be brought up to UL325 standards, there are no exceptions.
Click on the link below to obtain the UL325 PDF and CALL Wizard Works to set up a Gate System Review and Quote.
Our Standards
The standard to which vehicular gate operators are designed, manufactured, and tested is UL 325; Underwriters Laboratories Inc., Standard for Safety: Door, Drapery, Gate, Louver, and Window Operators and Systems. In addition to the UL 325 standard, vehicular gate operators must also be tested to UL 991; Tests for Safety-Related Controls Employing Solid-State Devices.
The UL 325 Standard has undergone significant revisions over the past several years. The purpose of the revisions is to create entrapment prevention criteria for vehicular gate operators and systems and to increase the overall safety of the product. The standard also calls for specific construction specifications for the vehicular gate itself (see ASTM F2200-02).
Keep in mind that this and other safety standards are written for YOUR protection. All new gate systems installed by Wizard Works are Ul 325 compliant. If you have an existing system, and to ensure UL 325 safety, Wizard Works will present you with different options for certain safety devices that are necessary to ensure a safe gate system. We STRONGLY suggest that you discuss these options with us and heed our recommendations regarding entrapment prevention devices and gate construction criteria. You should also refer to the manufacturer’s installation manual for more information on the safety provisions and requirements of your vehicular gate system. Some (but not all) of these safety devices and gate construction criteria are listed below.
Safety & Construction.
Refer to ASTM-F2200-02 for more information on the construction of the gate and associated hazards.
You should never install or have installed on your property, a vehicular gate operator that does not carry the “MARK” of a Nationally Recognized Testing Laboratory (NRTL) such as ETL or UL. This assures you that an independent third-party testing laboratory has tested the gate operator and has met all the safety requirements of the UL 325 safety standard.
What's Included
- Secondary entrapment prevention device or devices are installed in areas where an entrapment hazard exists. These devices include contact (pressure edges) and non-contact (photo-electric) sensors.
- Warning signs are placed in an area where they are visible from each side of the gate.
- Gate controls are installed in such a manner that a person operating the controls cannot come in contact with the gate or gate operator.
- The gate operator is appropriate for the construction and class of the gate.
- Rollers are guarded.
- Pinch points are eliminated or guarded.
- All openings in slide gate systems are guarded or screened from the bottom of the gate to a minimum of 48-inches above the ground to prevent a 2.25-inch diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position.